Datasheet
9–3
Recommended Operating Conditions (Continued)
TEST
CONDITION
MIN NOM MAX UNIT
Riit
Between TPA and TPB cable inputs, S100 operation ±0.8
Receive input
skew
Between TPA and TPB cable inputs, S200 operation ±0.55
ns
s
k
ew
Between TPA and TPB cable inputs, S400 operation ±0.5
9.3 Electrical Characteristics Over Recommended Operating Conditions
(unless otherwise noted)
PARAMETER OPERATION
TEST
CONDITIONS
MIN MAX UNIT
PCI
I
OH
= –0.5 mA 0.9DV
DD
V
OH
High-level output voltage
PCI
I
OH
= –2 mA 2.4
V
V
OH
High level
out ut
voltage
Miscellaneous
‡
I
OH
= –4 mA DV
DD
–0.6
V
PCI
I
OL
= 1.5 mA 0.1DV
DD
V
OL
Low-level output voltage
PCI
I
OL
= 6 mA 0.55
V
V
OL
Low level
out ut
voltage
Miscellaneous
‡
I
OL
= 4 mA 0.5
V
I
OZ
3-state output high-impedance Output pins 3.6 V V
O
= DV
DD
or GND ±20 µA
I
Low level input current
Input pins 3.6 V V
I
= GND ±20
A
I
IL
Low-level input current
I/O pins
†
3.6 V V
I
= GND ±20
µA
I
IH
High level in
p
ut current
PCI
†
3.6 V V
I
= DV
DD
±20
µA
I
IH
High-level input current
Others
†
3.6 V V
I
= DV
DD
±20
µA
†
For I/O terminals, input leakage (I
IL
and I
IH
) includes I
OZ
of the disabled output.
‡
Miscellaneous terminals are: GPIO2 (90), GPIO3 (89), SDA (92), SCL (91).