Datasheet

TSB41BA3D
SLLS959A DECEMBER 2008 REVISED MARCH 2009 ...............................................................................................................................................
www.ti.com
Table 2. Port Speed/Mode Selection
INPUT SELECTION RESULTING PORT, POWER CLASS, AND SELF-ID
MOD
PORT
(1)
S5_
E NO.
S4 S3 S2_ PC0 S1_ PC1 S0_ PC2 POWER CLASS SELF-ID
LKON
2 1 0
1 0 0 0 PC0 PC1 PC2 Bi T Bi T Bi T PC = (PC0, PC1, PC2) 1394b
2 0 0 1 PC0 PC1 PC2 DS T Bi T Bi T PC = (PC0, PC1, PC2) 1394b
3 0 1 0 PC0 PC1 PC2 DS T DS T Bi T PC = (PC0, PC1, PC2) 1394b
4 0 1 1 0 0 0 B1 S B1 S B1 S PC = 000 1394b
5 0 1 1 0 0 1 B2 S B2 S B2 S PC = 000 1394b
6 0 1 1 0 1 0 B4 S B4 S B4 S PC = 000 1394b
7 0 1 1 0 1 1 B2 S Bi T B4 S PC = 100 1394b
1394a
8 0 1 1 1 0 0 B1 S DS T DS T PC = 100
S100
(2)
9 0 1 1 1 0 1 DS T DS T B2 S PC = 100 1394b
10 0 1 1 1 1 0 DS T DS T B4 S PC = 100 1394b
11 0 1 1 1 1 1 B2 S DS T B4 S PC = 100 1394b
12 1 0 0 PC0 0 0 B1 S Bi T B1 S PC = PC0,0,0 (100 or 000) 1394b
13 1 0 0 PC0 0 1 B2 S Bi T B2 S PC = PC0,0,0 (100 or 000) 1394b
14 1 0 0 PC0 1 0 B4 S Bi T B4 S PC = PC0,0,0 (100 or 000) 1394b
15 1 0 0 PC0 1 1 B1 S Bi T B2 S PC = PC0,0,0 (100 or 000) 1394b
16 1 0 1 PC0 0 0 Bi T Bi T B1 S PC = PC0,0,0 (100 or 000) 1394b
17 1 0 1 PC0 0 1 Bi T Bi T B2 S PC = PC0,0,0 (100 or 000) 1394b
18 1 0 1 PC0 1 0 Bi T Bi T B4 S PC = PC0,0,0 (100 or 000) 1394b
19 1 0 1 PC0 1 1 B1 S Bi T B4 S PC = PC0,0,0 (100 or 000) 1394b
20 1 1 0 PC0 0 0 DS T Bi T B1 S PC = PC0,0,0 (100 or 000) 1394b
21 1 1 0 PC0 0 1 DS T Bi T B2 S PC = PC0,0,0 (100 or 000) 1394b
22 1 1 0 PC0 1 0 DS T Bi T B4 S PC = PC0,0,0 (100 or 000) 1394b
23 1 1 0 PC0 1 1 B1 S DS T B2 S PC = PC0,0,0 (100 or 000) 1394b
24 1 1 1 PC0 0 0 B1 S DS T B1 S PC = PC0,0,0 (100 or 000) 1394b
25 1 1 1 PC0 0 1 B2 S DS T B2 S PC = PC0,0,0 (100 or 000) 1394b
26 1 1 1 PC0 1 0 B4 S DS T B4 S PC = PC0,0,0 (100 or 000) 1394b
27 1 1 1 PC0 1 1 B1 S DS T B4 S PC = PC0,0,0 (100 or 000) 1394b
(1) LEGEND:
Bi = 1394b-2002 bilingual (S400b only Beta operating speed and data strobe: S400, S200, and S100 operating speeds)
DS = 1394a-2000, data strobe-only, S400, S200, and S100 operating speeds
B1 = 1394b-2002 Beta-only, S100b operating speed
B2 = 1394b-2002 Beta-only, S200b and S100b operating speeds
B4 = 1394b-2002 Beta-only, S400b, S200b, and S100b operating speeds
S = TPBIAS#_SD# terminal is in signal detect input mode
T = TPBIAS#_SD# terminal is in TPBIAS output mode
(2) Mode 8 must only be used to do an S100 home network translation. It must not be used as a nominal end equation mode.
12 Submit Documentation Feedback Copyright © 2008 2009, Texas Instruments Incorporated
Product Folder Link(s): TSB41BA3D