Datasheet
Electrical Characteristics
93
SGLS139A—October 2003 TSB12LV32-EP
9 Electrical Characteristics
9.1 Absolute Maximum Ratings Over Operating Free-Air Temperature Range (Unless
Otherwise Noted)
†
Supply voltage range, V
CC
−0.5 V to 3.6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage range, V
CC
5V −0.5 V to 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
−0.5 V to V
CC
5V + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
−0.5 V to V
CC
5V + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
)
(1)
±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
(2)
±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range −40°C to 110°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range −65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. This applies to external input and bidirectional buffers. For 5-V tolerant terminals, use V
I
> V
CC
5V.
2. This applies to external output and bidirectional buffers. For 5-V tolerant terminals, use V
I
> V
CC
5V.
DISSIPATION RATING TABLE
PACKAGE
T
A
≤
25
°
C
DERATING FACTOR
T
A
= 70
°
C
T
A
= 85
°
C
T
A
= 110
°
C
PACKAGE
T
A
≤ 25 C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70 C
POWER RATING
T
A
= 85 C
POWER RATING
T
A
= 110 C
POWER RATING
PZ 1500 mW 16.9 mW/°C 739.5 mW 486 mW 63.5 mW
9.2 Recommended Operating Conditions
MIN NOM MAX UNIT
Supply voltage, V
CC
3 3.3 3.6 V
Supply voltage, V
CC
5V 3 4.5 5.5 V
Input voltage, V
I
0 V
CC
5V V
Output voltage, V
O
†
0 V
CC
V
High-level input voltage, V
IH
2.2 V
CC
5V V
Low-level input voltage, V
IL
0 0.7 V
Input transition time, t
f
and t
r
(10% to 90%) 0 25 ns
Operating free-air temperature, T
A
−40 25 110 °C
†
This applies to external output buffers.