Datasheet

54
5.7 Cable PHY-Layer-Interface Switching Characteristics Over Recommended
Operating Free-Air Temperature Range, C
L
= 45 pF
(Unless Otherwise Noted) (see Note 3)
PARAMETER MIN MAX UNIT
t
d5
Delay time, SCLK to D0 D7 valid (see Figure 69) 1 11 ns
t
d6
Delay time, SCLK to D0 D7 invalid (see Figure 69) 1 11 ns
t
d7
Delay time, SCLK to D0 D7 invalid (see Figure 69) 1 11 ns
t
d8
Delay time, SCLK to CTL0 CTL1 valid (see Figure 69) 1 11 ns
t
d9
Delay time, SCLK to CTL0 CTL1 invalid (see Figure 69) 1 11 ns
t
d10
Delay time, SCLK to CTL0 CTL1 invalid (see Figure 69) 1 11 ns
t
d11
Delay time, SCLK to LREQ (see Figure 611) 1 11 ns
NOTE 3: These parameters are not production tested.
5.8 Miscellaneous Timing Requirements Over Recommended Operating
Free-Air Temperature Range (see Figure 613 and Note 3)
PARAMETER MIN MAX UNIT
t
c3
Cycle time, CYCLEIN (see Figure 613) 124.99 125.01 µs
t
w3(H)
Pulse duration, CYCLEIN high (see Figure 613) 0.08 120 µs
t
w3(L)
Pulse duration, CYCLEIN low (see Figure 613) 4 µs
NOTE 3: These parameters are not production tested.
5.9 Miscellaneous Signal Switching Characteristics Over Recommended
Operating Free-Air Temperature Range (see Note 3)
PARAMETER MIN MAX UNIT
t
d12
Delay time, SCLK to INT (see Figure 612) 4 18 ns
t
d13
Delay time, SCLK to INT (see Figure 612) 4 18 ns
t
d14
Delay time, SCLK to CYCLEOUT (see Figure 614) 4 16 ns
t
d15
Delay time, SCLK to CYCLEOUT (see Figure 614) 4 16 ns
NOTE 3: These parameters are not production tested.