Datasheet
Recommended Operating Conditions
(1)
Electrical Characteristics
TS5V330
www.ti.com
.............................................................................................................................................................. SCDS164D – MAY 2004 – REVISED JUNE 2009
MIN MAX UNIT
V
CC
Supply voltage range 4 5.5 V
V
IH
High-level control input voltage range ( EN, IN) 2 5.5 V
V
IL
Low-level control input voltage range ( EN, IN) 0 0.8 V
V
ANALOG
Analog I/O voltage range 0 Vcc V
T
A
Operating free-air temperature range – 40 85 ° C
(1) All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
over recommended operating free-air temperature range, V
CC
= 5 V ± 10% (unless otherwise noted)
PARAMETER TEST CONDITIONS
(1)
MIN TYP
(2)
MAX UNIT
V
IK
EN, IN V
CC
= 4.5 V, I
IN
= – 18 mA – 1.8 V
V
hys
EN, IN 150 mV
I
IH
EN, IN V
CC
= 5.5 V, V
IN
and V
EN
= V
CC
± 1 µ A
I
IL
EN, IN V
CC
= 5.5 V, V
IN
and V
EN
= GND ± 1 µ A
I
OZ
(3)
V
CC
= 5.5 V, V
O
= 0 to 5.5 V, V
I
= 0, Switch OFF ± 1 µ A
I
OS
(4)
V
CC
= 5.5 V, V
O
= 0.5 V
CC,
V
I
= 0, Switch ON 50 mA
I
off
V
CC
= 0 V, V
O
= 0 to 5.5 V, V
I
= 0 1 µ A
I
CC
V
CC
= 5.5 V, I
I/O
= 0, Switch ON or OFF 3 µ A
Δ I
CC
EN, IN V
CC
= 5.5 V, One input at 3.4 V, Other inputs at V
CC
or GND 2.5 mA
I
CCD
V
EN
= GND, V
CC
= 5.5 V, D and S ports open, V
IN
input switching 50% duty cycle 0.25 mA/MHz
V
IN
of V
EN
= 0,
C
IN
EN, IN 3.5 pF
f = 1 MHz
D port 6
C
OFF
V
I
= 0, f = 1 MHz, Outputs open, Switch OFF pF
S port 4
C
ON
V
I
= 0, f = 1 MHz, Outputs open, Switch ON 14 pF
V
I
= 1 V, I
O
= 13 mA, R
L
= 75 Ω 3 7
r
on
(5)
V
CC
= 4.5 V Ω
V
I
= 2 V, I
O
= 26 mA, R
L
= 75 Ω 7 10
(1) V
I
, V
O
, I
I
, and I
O
refer to I/O pins.
(2) All typical values are at V
CC
= 5 V (unless otherwise noted), T
A
= 25 ° C.
(3) For I/O ports, I
OZ
includes the input leakage current.
(4) The I
OS
test is applicable to only one ON channel at a time. The duration of this test is less than 1 s.
(5) Measured by the voltage drop between the D and S terminals at the indicated current through the switch. ON-state resistance is
determined by the lower of the voltages of the two (D or S) terminals.
Copyright © 2004 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TS5V330