Datasheet
Ω
TS5V330C
www.ti.com
SCDS276B –APRIL 2009–REVISED DECEMBER 2009
PARAMETER MEASUREMENT INFORMATION (continued)
For additional information, refer to the TI application report, Measuring Differential Gain and Phase, literature number
SLOA040.
Figure 6. Test Circuit for Differential Gain/Phase Measurement
The differential gain and phase is measured at the output of the ON channel. For example, when V
IN
= 0, V
EN
=
0, and D
A
is the input, the output is measured at S
1A
.
HP8753ES Setup
Average = 20
RBW = 300 Hz
Smoothing = 2%
V
BIAS
= 0 to 1 V
ST = 1.381 s.
P1 = –7 dBM
CW frequency = 3.58 MHz
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): TS5V330C