Datasheet
Ω
TS5V330C
SCDS276B –APRIL 2009–REVISED DECEMBER 2009
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 7. Test Circuit for Frequency Response, Crosstalk, and OFF-Isolation
The frequency response is measured at the output of the ON channel. For example, when V
IN
= 0, V
EN
= 0, and
D
A
is the input, the output is measured at S
1A
. All unused analog I/O ports are held at V
CC
or GND.
The crosstalk is measured at the output of the non-adjacent ON channel. For example, when V
IN
= 0, V
EN
= 0,
and D
A
is the input, the output is measured at S
1B
. All unused analog I/O ports are held at V
CC
or GND.
The off-isolation is measured at the output of the OFF channel. For example, when V
IN
= 0, V
EN
= V
CC
, and D
A
is
the input, the output is measured at S
1A
. All unused analog I/O ports are held at V
CC
or GND.
HP8753ES Setup
Average = 4
RBW = 3 kHz
Smoothing = 0%
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
10 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TS5V330C