Datasheet
Table Of Contents
- FEATURES
- Applications
- Description
- Absolute Minimum and Maximum Ratings
- Electrical Characteristics for 5-V Supply
- Electrical Characteristics for 5-V Supply (Continued)
- Electrical Characteristics for 3.3-V Supply
- Electrical Characteristics for 3.3-V Supply (Continued)
- Electrical Characteristics for 2.5-V Supply
- Electrical Characteristics for 2.5-V Supply (Continued)
- Electrical Characteristics for 1.8-V Supply
- Electrical Characteristics for 1.8-V Supply (Continued)
- TYPICAL PERFORMANCE
- PARAMETER MEASUREMENT INFORMATION

www.ti.com
Electrical Characteristics for 3.3-V Supply
(1)
(Continued)
TS5A4624
1- Ω SPDT ANALOG SWITCH
5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
SLYS014A – DECEMBER 2005 – REVISED AUGUST 2006
V
+
= 3 V to 3.6 V, T
A
= –40 ° C to 85 ° C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Dynamic
25 ° C 3.3 V 4 16 25
V
COM
= V
+
, C
L
= 35 pF,
Turn-on time t
ON
ns
3 V to
R
L
= 50 Ω , See Figure 17
Full 2 27
3.6 V
25 ° C 3.3 V 1 5.5 8
V
COM
= V
+
, C
L
= 35 pF,
Turn-off time t
OFF
ns
3 V to
R
L
= 50 Ω , See Figure 17
Full 1 11
3.6 V
25 ° C 3.3 V 2 12 20
Break-before- V
NC
= V
NO
= V
+
, C
L
= 35 pF,
t
BBM
ns
3 V to
make time R
L
= 50 Ω , See Figure 18
Full 2 25
3.6 V
V
GEN
= 0, C
L
= 1 nF,
Charge injection Q
C
25 ° C 3.3 V 9 pC
R
GEN
= 0, See Figure 22
NC, NO
C
NC(OFF)
, V
NC
or V
NO
= V
+
or GND,
OFF See Figure 16 25 ° C 3.3 V 18 pF
C
NO(OFF)
Switch OFF,
capacitance
NC, NO C
NC(ON)
, V
NC
or V
NO
= V
+
or GND,
See Figure 16 25 ° C 3.3 V 55 pF
ON capacitance C
NO(ON)
Switch ON,
COM V
COM
= V
+
or GND,
C
COM(ON)
See Figure 16 25 ° C 3.3 V 55 pF
ON capacitance Switch ON,
Digital input
C
I
V
I
= V
+
or GND, See Figure 16 25 ° C 3.3 V 2 pF
capacitance
R
L
= 50 Ω ,
Bandwidth BW See Figure 19 25 ° C 3.3 V 90 MHz
Switch ON,
R
L
= 50 Ω , Switch OFF,
OFF isolation O
ISO
25 ° C 3.3 V –63 dB
f = 1 MHz, See Figure 20
R
L
= 50 Ω , Switch ON,
Crosstalk X
TALK
25 ° C 3.3 V –63 dB
f = 1 MHz, See Figure 21
Total harmonic R
L
= 600 Ω , f = 20 Hz to 20 kHz,
THD 25 ° C 3.3 V 0.01 %
distortion C
L
= 50 pF, See Figure 23
Supply
25 ° C 10 50
Positive supply
I
+
V
I
= V
+
or GND, Switch ON or OFF 3.6 V nA
current
Full 100
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
7
Submit Documentation Feedback