Datasheet

www.ti.com
Electrical Characteristics for 3.3-V Supply
(1)
TS5A4624
1- SPDT ANALOG SWITCH
5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
SLYS014A DECEMBER 2005 REVISED AUGUST 2006
V
+
= 3 V to 3.6 V, T
A
= –40 ° C to 85 ° C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal V
COM
, V
NO
,
0 V
+
V
range V
NC
25 ° C 1.3 1.6
Peak ON 0 (V
NO
or V
NC
) V
+
, Switch ON,
r
peak
3 V
resistance I
COM
= –100 mA, See Figure 13
Full 2
25 ° C 1.2 1.5
ON-state V
NO
or V
NC
= 2 V, Switch ON,
r
on
3 V
resistance I
COM
= –100 mA, See Figure 13
Full 1.7
ON-state 25 ° C 0.1 0.15
resistance
V
NO
or V
NC
= 2 V, 0.8 V, Switch ON,
match r
on
3 V
I
COM
= –100 mA, See Figure 13
Full 0.15
between
channels
0 (V
NO
or V
NC
) V
+
, Switch ON,
25 ° C 0.2
ON-state
I
COM
= –100 mA, See Figure 13
resistance r
on(flat)
3 V
25 ° C 0.15 0.3
V
NO
or V
NC
= 2 V, 0.8 V, Switch ON,
flatness
I
COM
= –100 mA, See Figure 13
Full 0.3
V
NC
or V
NO
= 1 V, V
COM
= 1 V to 3 V, 25 ° C –20 2 20
I
NC(OFF)
, Switch OFF,
or 3.6 V nA
NC, NO
I
NO(OFF)
See Figure 14
Full –50 50
V
NC
or V
NO
= 3 V, V
COM
= 1 V to 3 V,
OFF leakage
current 25 ° C –1 0.2 1
I
NC(PWROFF)
, V
NC
or V
NO
= 0 to 3.6 V, Switch OFF,
0 V µ A
I
NO(PWROFF)
V
COM
= 3.6 V to 0, See Figure 14
Full –15 15
NC, NO V
NC
or V
NO
= 1 V, V
COM
= Open, 25 ° C –10 2 10
I
NC(ON)
, Switch ON,
ON leakage or 3.6 V nA
I
NO(ON)
See Figure 15
Full –20 20
current V
NC
or V
NO
= 3 V, V
COM
= Open,
COM 25 ° –1 0.2 1
V
NC
or V
NO
= 3.6 V to 0, Switch OFF,
OFF leakage I
COM(PWROFF)
0 V µ A
V
COM
= 0 to 3.6 V, See Figure 14
Full –15 15
current
COM V
NC
or V
NO
= Open, V
COM
= 1 V, 25 ° C –10 2 10
Switch ON,
ON leakage I
COM(ON)
or 3.6 V nA
See Figure 15
Full –20 20
current V
NC
or V
NO
= Open, V
COM
= 3 V,
Digital Input (IN)
Input logic high V
IH
Full 2.4 5.5 V
Input logic low V
IL
Full 0 0.8 V
25 ° C –2 2
Input leakage
I
IH
, I
IL
V
I
= 5.5 V or 0 3.6 V nA
current
Full –100 100
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
6