ELECTRICAL CHARACTERISTICS FOR 5-V SUPPLY
(1)
TS5A3359
1- Ω SP3T ANALOG SWITCH
5-V/3.3-V SINGLE-CHANNEL 3:1 MULTIPLEXER/DEMULTIPLEXER
SCDS214C – OCTOBER 2005 – REVISED JANUARY 2008
V
+
= 4.5 V to 5.5 V, T
A
= – 40 ° C to 85 ° C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal
V
COM
, V
NO
0 V
+
V
range
25 ° C 0.8 1.1
Peak ON 0 ≤ (V
NO
) ≤ V
+
, Switch ON,
r
peak
4.5 V Ω
resistance I
COM
= – 100 mA, See Figure 19
Full 1.5
25 ° C 0.7 0.9
ON-state V
NO
= 2.5 V, Switch ON,
r
on
4.5 V Ω
resistance I
COM
= – 100 mA, See Figure 19
Full 1.1
ON-state 25 ° C 0.1 0.1
resistance
V
NO
= 2.5 V, Switch ON,
match Δ r
on
4.5 V Ω
I
COM
= – 100 mA, See Figure 19
Full 0.1
between
channels
0 ≤ (V
NO
) ≤ V
+
, Switch ON,
25 ° C 0.15
I
COM
= – 100 mA, See Figure 19
ON-state
resistance r
on(flat)
4.5 V Ω
V
NO
= 1 V, 1.5 V, 2.5 25 ° C 0.1 0.25
Switch ON,
flatness
V,
See Figure 19
Full 0.25
I
COM
= – 100 mA,
25 ° C – 20 5 20
V
NO
= 1 V or 4.5 V, Switch OFF,
I
NO(OFF)
5.5 V nA
NO
V
COM
= 1 V to 4.5 V, See Figure 20
Full – 150 150
OFF leakage
25 ° C – 1 0.8 1
V
NO
= 0 to 5.5 V, Switch OFF,
current
I
NO(PWROFF)
0 V µ A
V
COM
= 5.5 V to 0, See Figure 20
Full – 25 25
NO 25 ° C – 30 5 30
V
NO
= 1 V or 4.5 V, Switch ON,
ON leakage I
NO(ON)
5.5 V nA
V
COM
= Open, See Figure 20
Full – 220 220
current
25 ° C – 25 8 25
V
NO
= 4.5 V or 1 V, Switch OFF,
I
COM(OFF)
5.5 V nA
COM
V
COM
= 1 V or 4.5 V, See Figure 20
Full – 250 250
OFF leakage
25 ° C – 8 0.1 8
V
COM
= 0 to 5.5 V, Switch OFF,
current
I
COM(PWROFF)
0 V µ A
V
NO
= 5.5 V to 0, See Figure 20
Full – 50 50
COM 25 ° C – 30 5 30
V
NO
= Open, Switch ON,
ON leakage I
COM(ON)
5.5 V nA
V
COM
= 1 V or 4.5 V, See Figure 20
Full – 220 220
current
Digital Control Inputs (IN1, IN2)
(2)
Input logic
V
IH
Full 2.4 5.5 V
high
Input logic low V
IL
Full 0 0.8 V
25 ° C – 2 2
Input leakage
I
IH
, I
IL
V
I
= 5.5 V or 0 5.5 V µ A
current
Full – 20 20
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(2) All unused digital inputs of the device must be held at V
+
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Copyright © 2005 – 2008, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TS5A3359