Datasheet

www.ti.com
TS5A3359
1- SP3T ANALOG SWITCH
5-V/3.3-V SINGLE-CHANNEL 3:1 MULTIPLEXER/DEMULTIPLEXER
SCDS214C OCTOBER 2005 REVISED JANUARY 2008
PIN DESCRIPTION
PIN NO. NAME DESCRIPTION
1 NO0 Normally open
2 NO1 Normally open
3 NO2 Normally open
4 GND Digital ground
5 IN2 Digital control to connect COM to NO
6 IN1 Digital control to connect COM to NO
7 COM Common
8 V
+
Power supply
PARAMETER DESCRIPTION
SYMBOL DESCRIPTION
V
COM
Voltage at COM
V
NO
Voltage at NO
r
on
Resistance between COM and NC or COM and NO ports when the channel is ON
r
peak
Peak on-state resistance over a specified voltage range
Δ r
on
Difference of r
on
between channels in a specific device
r
on(flat)
Difference between the maximum and minimum value of r
on
in a channel over the specified range of conditions
I
NO(OFF)
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state
I
NO(PWROFF)
Leakage current measured at the NO port during the power-down condition, V
+
= 0.
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output
I
NO(ON)
(COM) open
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the ON state
I
COM(ON)
and the output (NC or NO) open
I
COM(OFF)
Leakage current measured at the COM port during the power-down condition, V
+
= 0
I
COM(PWROFF)
Leakage current measured at the COM port during the power-down condition, V
+
= 0.
V
IH
Minimum input voltage for logic high for the control input (IN)
V
IL
Maximum input voltage for logic low for the control input (IN)
V
I
Voltage at the control input (IN)
I
IH
, I
IL
Leakage current measured at the control input (IN)
Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation
t
ON
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning ON.
Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation
t
OFF
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning OFF.
Break-before-make time. This parameter is measured under the specified range of conditions and by the propagation
t
BBM
delay between the output of two adjacent analog channels (NC and NO) when the control signal changes state.
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NO or COM)
Q
C
output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control
input.Charge injection, Q
C
= C
L
× Δ V
COM
, C
L
is the load capacitance and Δ V
COM
is the change in analog output voltage.
C
NO(OFF)
Capacitance at the NO port when the corresponding channel (NO to COM) is OFF
C
NO(ON)
Capacitance at the NO port when the corresponding channel (NO to COM) is ON
C
COM(ON)
Capacitance at the COM port when the corresponding channel (COM to NO) is ON
C
COM(OFF)
Capacitance at the COM port when the corresponding channel (COM to NO) is OFF
C
I
Capacitance of control input (IN)
OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific
O
ISO
frequency, with the corresponding channel (NC to COM or NO to COM) in the OFF state.
Crosstalk is a measurement of unwanted signal coupling from an ON channel to an OFF channel (NC to NO or NO to
X
TALK
NC). This is measured in a specific frequency and in dB.
BW Bandwidth of the switch. This is the frequency in which the gain of an ON channel is 3 dB below the DC gain.
14 Submit Documentation Feedback Copyright © 2005 2008, Texas Instruments Incorporated
Product Folder Link(s): TS5A3359