Datasheet
TS5A3166
www.ti.com
SCDS186B –FEBRUARY 2005–REVISED SEPTEMBER 2013
Electrical Characteristics for 5-V Supply
(1)
(continued)
V
+
= 4.5 V to 5.5 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V+ MIN TYP MAX UNIT
Dynamic
25°C 5 V 2.5 4.5 7
V
COM
= V
+
, C
L
= 35 pF,
Turn-on time t
ON
ns
4.5 V to
R
L
= 50 Ω, See Figure 17
Full 1.5 7.5
5.5 V
25°C 5 V 6 9 11.5
V
COM
= V
+
, C
L
= 35 pF,
Turn-off time t
OFF
ns
4.5 V to
R
L
= 50 Ω, See Figure 17
Full 4 12.5
5.5 V
V
GEN
= 0, C
L
= 1 nF,
Charge injection Q
C
25°C 5 V 1 pC
R
GEN
= 0 , See Figure 20
NO V
NO
= V
+
or GND,
C
NO(OFF)
See Figure 16 25°C 5 V 19 pF
OFF capacitance Switch OFF,
COM V
COM
= V
+
or GND,
C
COM(OFF)
See Figure 16 25°C 5 V 18 pF
OFF capacitance Switch OFF,
NO V
NO
= V
+
or GND,
C
NO(ON)
See Figure 16 25°C 5 V 35.5 pF
ON capacitance Switch ON,
COM V
COM
= V
+
or GND,
C
COM(ON)
See Figure 16 25°C 5 V 35.5 pF
ON capacitance Switch ON,
Digital input
C
I
V
I
= V
+
or GND, See Figure 16 25°C 5 V 2 pF
capacitance
R
L
= 50 Ω,
Bandwidth BW See Figure 18 25°C 5 V 200 MHz
Switch ON,
R
L
= 50 Ω, Switch OFF,
OFF isolation O
ISO
25°C 5 V –64 dB
f = 1 MHz, See Figure 19
Total harmonic R
L
= 600 Ω, f = 20 Hz to 20 kHz,
THD 25°C 5 V 0.005 %
distortion C
L
= 50 pF, See Figure 21
Supply
25°C 0.01 0.1
Positive supply
I
+
V
I
= V
+
or GND, Switch ON or OFF 5.5 V μA
current
Full 0.5
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TS5A3166