Datasheet
TS5A3166
www.ti.com
SCDS186B –FEBRUARY 2005–REVISED SEPTEMBER 2013
Electrical Characteristics for 1.8-V Supply
(1)
(continued)
V
+
= 1.65 V to 1.95 V, T
A
= –40°C to 85°C (unless otherwise noted))
PARAMETER SYMBOL TEST CONDITIONS T
A
V+ MIN TYP MAX UNIT
Dynamic
25°C 1.8 V 3 9 18
V
COM
= V
+
, C
L
= 35 pF,
Turn-on time t
ON
ns
1.65 V to
R
L
= 50 Ω, See Figure 17
Full 1 20
1.95 V
25°C 1.8 V 5 10 15.5
V
COM
= V
+
, C
L
= 35 pF,
Turn-off time t
OFF
ns
1.65 V to
R
L
= 50 Ω, See Figure 17
Full 4 18.5
1.95 V
V
GEN
= 0, C
L
= 1 nF,
Charge injection Q
C
25°C 1.8 V 2 pC
R
GEN
= 0, See Figure 21
NO V
NO
= V
+
or GND,
C
NO(OFF)
See Figure 16 25°C 1.8 V 19.5 pF
OFF capacitance Switch OFF,
COM V
COM
= V
+
or GND,
C
COM(OFF)
See Figure 16 25°C 1.8 V 18.5 pF
OFF capacitance Switch OFF,
NO V
NO
= V
+
or GND,
C
NO(ON)
See Figure 16 25°C 1.8 V 36.5 pF
ON capacitance Switch ON,
COM V
COM
= V
+
or GND,
C
COM(ON)
See Figure 16 25°C 1.8 V 36.5 pF
ON capacitance Switch ON,
Digital input
C
I
V
I
= V
+
or GND, See Figure 16 25°C 1.8 V 2 pF
capacitance
R
L
= 50 Ω,
Bandwidth BW See Figure 18 25°C 1.8 V 150 MHz
Switch ON,
R
L
= 50 Ω, Switch OFF,
OFF isolation O
ISO
25°C 1.8 V –62 dB
f = 1 MHz, See Figure 19
Total harmonic R
L
= 600 Ω, f = 20 Hz to 20 kHz
THD 25°C 1.8 V 0.055 %
distortion C
L
= 50 pF, See Figure 21
Supply
25°C 0.001 0.01
Positive supply
I
+
V
I
= V
+
or GND, Switch ON or OFF 1.95 V μA
current
Full 0.15
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links: TS5A3166