Electrical Characteristics for 1.8-V Supply
(1)
V
+
= 1.65 V to 1.95 V, T
A
= 40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog
Switch
Analog signal V
COM
, V
NO
,
0 V
+
V
range V
NC
25°C 5.5 25
Peak ON 0 (V
NO
or V
NC
) V
+
, Switch ON,
r
peak
1.65 V
resistance I
COM
= 2 mA, See Figure 13
Full 30
25°C 2 2.7
ON-state V
NO
or V
NC
= 1.5 V, Switch ON,
r
on
1.65 V
resistance I
COM
= 2 mA, See Figure 13
Full 3.1
ON-state 25°C 0.16 0.3
resistance
V
NO
or V
NC
= 1.5 V, Switch ON,
matching Δr
on
1.65 V
I
COM
= 2 mA, See Figure 13
Full 0.3
between
channels
0 (V
NO
or V
NC
) V
+
, Switch ON,
25°C 3
ON-state
I
COM
= 2 mA, See Figure 13
resistance r
on(flat)
1.65 V
25°C 3 20
V
NO
or V
NC
= 0.6 V, 1.5 V, Switch ON,
flatness
I
COM
= 2 mA, See Figure 13
Full 25
V
NC
or V
NO
= 0.3 V, 25°C 20 1.5 20
V
COM
= 1.65 V,
I
NC(OFF)
, Switch OFF,
or 1.95 V nA
NC, NO
I
NO(OFF)
See Figure 14
Full 50 50
V
NC
or V
NO
= 1.65 V,
OFF leakage
V
COM
= 0.3 V,
current
25°C 1 0.1 1
I
NC(PWROFF)
, V
NC
or V
NO
= 0 to 1.95 V, Switch OFF,
0 V μA
I
NO(PWROFF)
V
COM
= 1.95 V to 0, See Figure 14
Full 10 10
V
NC
or V
NO
= 0.3 V, 25°C 20 1.5 20
NC, NO V
COM
= Open,
I
NC(ON)
, Switch ON,
ON leakage or 1.95 V nA
I
NO(ON)
See Figure 15
Full 50 50
current V
NC
or V
NO
= 1.65 V,
V
COM
= Open,
V
NC
or V
NO
= 1.65 V, 25°C 20 1.5 20
V
COM
= 0.3 V,
Switch OFF,
I
COM(OFF)
or 1.95 V nA
COM
See Figure 14
Full 50 50
V
NC
or V
NO
= 0.3 V,
OFF leakage
V
COM
= 1.65 V,
current
25°C 1 0.06 1
V
NC
or V
NO
= 1.95 V to 0, Switch OFF,
I
COM(PWROFF)
0 V μA
V
COM
= 0 to 1.95 V, See Figure 14
Full 10 10
V
NC
or V
NO
= Open, 25°C 20 1.5 20
COM V
COM
= 0.3 V,
Switch ON,
ON leakage I
COM(ON)
or 1.95 V nA
See Figure 15
Full 50 50
current V
NC
or V
NO
= Open,
V
COM
= 1.65 V,
Digital Control Inputs (IN, EN)
(2)
Input logic high V
IH
Full 1.5 5.6 V
Input logic low V
IL
Full 0 0.6 V
25°C 100 25 100
Input leakage
I
IH
, I
IL
V
I
= 5.5 V or 0 1.95 V nA
current
Full 100 100
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(2) All unused digital inputs of the device must be held at V
+
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
10 Submit Documentation Feedback Copyright © 20052012, Texas Instruments Incorporated
Product Folder Link(s): TS5A3154