Datasheet
TS5A23166
SCDS196G –MAY 2005–REVISED FEBRUARY 2013
www.ti.com
SUMMARY OF CHARACTERISTICS
(1)
Dual Single Pole, Single Throw
Configuration
(2 × SPST)
Number of channels 2
ON-state resistance (r
on
) 0.9 Ω
ON-state resistance match (Δr
on
) 0.1 Ω
ON-state resistance flatness
0.25 Ω
(r
on(flat)
)
Turn-on/turn-off time (t
ON
/t
OFF
) 7.5 ns/9 ns
Charge injection (Q
C
) 6 pC
Bandwidth (BW) 150 MHz
OFF isolation (O
ISO
) –62 dB at 1 MHz
Crosstalk (X
TALK
) –85 dB at 1 MHz
Total harmonic distortion (THD) 0.005%
Leakage current (I
COM(OFF)
) ±20 nA
Power-supply current (I
+
) 0.1 μA
Package options 8-pin SSOP, VSSOP, and WCSP
(1) V
+
= 5 V, T
A
= 25°C
FUNCTION TABLE
NO TO COM,
IN
COM TO NO
L OFF
H ON
Absolute Maximum Ratings
(1) (2)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
+
Supply voltage range
(3)
–0.5 6.5 V
V
NO
Analog voltage range
(3) (4) (5)
–0.5 V
+
+ 0.5 V
V
COM
I
K
Analog port diode current V
NO
, V
COM
< 0 –50 mA
On-state switch current –200 200
I
NO
V
NO,
V
COM
= 0 to V
+
mA
I
COM
On-state peak switch current
(6)
–400 400
V
I
Digital input voltage range
(3) (4)
–0.5 6.5 V
I
IK
Digital input clamp current V
I
< 0 –50 mA
I
+
Continuous current through V
+
100 mA
I
GND
Continuous current through GND –100 100 mA
DCU package 227
θ
JA
Package thermal impedance
(7)
°C/W
YZT/YZP package 102
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(3) All voltages are with respect to ground, unless otherwise specified.
(4) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(5) This value is limited to 5.5 V maximum.
(6) Pulse at 1-ms duration < 10% duty cycle.
(7) The package thermal impedance is calculated in accordance with JESD 51-7.
2 Submit Documentation Feedback Copyright © 2005–2013, Texas Instruments Incorporated
Product Folder Links: TS5A23166