Datasheet
www.ti.com
NC
NO
COM
V
NC
V
COM
Channel OFF: NC to COM
Network Analyzer Setup
Source Power = 0 dBm
(632-mV P-P at 50- load)
DC Bias = 350 mV
50
V
+
GND
50
50
Network Analyzer
Source
Signal
V
I
+
V
I
= V
+
or GND
IN
NC
NO
50
50
V
NC
V
COM
Channel ON: NC to COM
Network Analyzer Setup
Source Power = 0 dBm
(632-mV P-P at 50- load)
DC Bias = 350 mV
50
V
+
GND
V
NO
Source
Signal
Channel OFF: NO to COM
Network Analyzer
V
I
+
V
I
= V
+
or GND
IN
TS5A23160
0.9- Ω DUAL SPDT ANALOG SWITCH
5-V/3.3-V 2-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
SCDS210A – AUGUST 2005 – REVISED APRIL 2006
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 21. OFF Isolation (O
ISO
)
A. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, Z
O
= 50 Ω , t
r
< 5 ns,
t
f
< 5 ns.
B. C
L
includes probe and jig capacitance.
Figure 22. Crosstalk (X
TALK
)
19