Datasheet
TS5A22366
www.ti.com
SCDS262B –JANUARY 2009–REVISED MAY 2013
ELECTRICAL CHARACTERISTICS FOR 2.5-V SUPPLY
(1)
V
+
= 2.25 V to 2.7 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal V
COM
,
V
+
– 5.5 V
+
Ω
range V
NO
, V
NC
V
NC
or V
NO
= V
+
, 1.5 V, 25°C 1 1.8
ON-state Switch ON,
r
on
V
+
– 5.5 V 2.25 V Ω
resistance See Figure 15
Full 2
I
COM
= –100 mA,
ON-state 25°C 0.05 1
resistance match V
NC
or V
NO
= 1.5 V, Switch ON,
Δr
on
2.25 V Ω
between I
COM
= –100 mA, See Figure 15
Full 1
channels
ON-state V
NC
or V
NO
= V
+
, 1.5 V, 25°C 0.53 1.5
Switch ON,
resistance r
on(flat)
V
+
– 5.5 V 2.25 V Ω
See Figure 16
Full 1.6
flatness I
COM
= –100 mA,
V
NC
= 2.25, V
+
– 5.5 V 25°C –50 50
V
COM
= V
+
– 5.5 V,
2.25,
NC, NO V
NO
= Open,
I
NC(OFF)
, Switch OFF,
OFF leakage or 2.7 V nA
I
NO(OFF)
See Figure 16
Full –375 375
current V
NO
= 2.25, V
+
– 5.5 V
V
COM
= V
+
– 5.5 V,
2.25,
V
NC
= Open,
COM 25°C –50 50
V
NC
and V
NO
= Open,
ON leakage I
COM(ON)
See Figure 17 2.7 V nA
V
COM
= V
+
,V
+
– 5.5 V,
Full –375 375
current
Digital Control Inputs (IN, EN)
(2)
Input logic high V
IH
Full 1.05 5.5 V
Input logic low V
IL
Full 0.65 V
25°C –700 700
Input leakage
I
IH
, I
IL
V
IN
= 1.8 V or GND 2.7 V nA
current
Full –700 700
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(2) All unused digital inputs of the device must be held at V
+
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TS5A22366