Datasheet
TS5A22362, TS5A22364
www.ti.com
SCDS261E –MARCH 2008–REVISED MAY 2013
ELECTRICAL CHARACTERISTICS FOR 3.3-V SUPPLY
(1)
V
+
= 3 V to 3.6 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal V
COM
,
V
+
– 5.5 V
+
V
range V
NO
, V
NC
V
NC
or V
NO
≤ V
+
, 25°C 0.61 0.87
COM to NO or
ON-state 1.5 V,
r
on
NC, 3 V Ω
resistance V
+
– 5.5 V,
Full 0.97
See Figure 16
I
COM
= –100 mA,
ON-state 25°C 0.024 0.13
COM to NO or
resistance match V
NC
or V
NO
= 1.5 V,
Δr
on
NC, 3 V Ω
between I
COM
= –100 mA,
Full 0.13
See Figure 16
channels
V
NC
or V
NO
≤ V
+
, 25°C 0.12 0.46
ON-state COM to NO or
1.5 V,
resistance r
on(flat)
NC, 3 V Ω
V
+
– 5.5 V,
Full 0.5
flatness See Figure 16
I
COM
= –100 mA,
Shunt switch
resistance
r
SH
I
NO
or I
NC
= 10 mA Full 3 V 25 37 Ω
(TS5A22364
only)
V
NC
= 3 V, V
+
– 5.5 V 25°C –50 50
V
COM
= V
+
– 5.5 V, 3 V
NC, NO V
NO
= Open
OFF leakage COM to NO
I
NC(OFF)
,
current or See Figure 17 3.6 V nA
I
NO(OFF)
Full –375 375
(TS5A22362 V
NO
= 3 V, V
+
– 5.5 V,
only) V
COM =
V
+
– 5.5 V, 3 V
V
NC
= Open
COM to NC
COM COM to NO or 25°C –50 50
V
NC
and V
NO
= Open,
ON leakage I
COM(ON)
NC, 3.6 V nA
V
COM
= V
+
,V
+
– 5.5 V,
Full –375 375
current See Figure 18
Digital Control Inputs (IN)
(2)
Input logic high V
IH
Full 1.4 5.5 V
Input logic low V
IL
Full 0.8 V
25°C –250 250
Input leakage
I
IH
, I
IL
V
IN
= V
+
or 0 3.6 V nA
current
Full –250 250
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(2) All unused digital inputs of the device must be held at V
+
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: TS5A22362 TS5A22364