Datasheet
TS5A2066
www.ti.com
SCDS184D –JANUARY 2005–REVISED APRIL 2010
Electrical Characteristics for 2.5-V Supply
(1)
V
+
= 2.3 V to 2.7 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal
V
COM
, V
NO
0 V
+
V
range
0 ≤ V
NO
≤ V
+
, 25°C 20 22
ON-state Switch ON,
r
on
2.3 V Ω
I
COM
= –8 mA,
resistance See Figure 13
Full 30
ON-state 25°C 0.04 0.5 1.5
resistance match V
NO
= 1.6 V, Switch ON,
Δr
on
2.3 V Ω
between I
COM
= –8 mA, SeeFigure 13
Full 0.02 5
channels
ON-state 25°C 12 16 18
0 ≤ V
NO
≤ V
+
, Switch ON,
resistance r
on(flat)
2.3 V Ω
I
COM
= –8 mA, See Figure 13
Full 15 25
flatness
V
NO
= 0.5 V, 25°C –30 –5.5 30
NO V
COM
= 2.2 V,
Switch OFF,
OFF leakage I
NO(OFF)
or 2.7 V nA
See Figure 14
Full –40 40
current V
NO
= 2.2 V,
V
COM
= 0.5 V,
V
COM
= 0.5 V, 25°C –50 –7.5 50
COM V
NO
= 2.2 V,
Switch OFF,
OFF leakage I
COM(OFF)
or 2.7 V nA
See Figure 14
Full –50 50
current V
COM
= 2.2 V,
V
NO
= 0.5 V,
V
NO
= 0.5 V, 25°C –40 –5 40
NO V
COM
= Open,
Switch ON,
ON leakage I
NO(ON)
or 2.7 V nA
See Figure 15
Full –40 40
current V
NO
= 2.2 V,
V
COM
= Open,
V
COM
= 0.5 V, 25°C –70 –12 70
COM V
NO
= Open,
Switch ON,
ON leakage I
COM(ON)
or 2.7 V nA
See Figure 15
Full –70 70
current V
COM
= 2.2 V,
V
NO
= Open,
Digital Control Input (IN)
Input logic high V
IH
Full V
+
× 0.7 5.5 V
Input logic low V
IL
Full 0 V
+
× 0.3 V
25°C –0.1 0.05 0.1
Input leakage
I
IH
, I
IL
V
I
= 5.5 V or 0 2.7 V mA
current
Full –1 1
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
Copyright © 2005–2010, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): TS5A2066