Datasheet
TS5A1066
SCDS185C –JANUARY 2005–REVISED SEPTEMBER 2012
www.ti.com
Electrical Characteristics for 1.8-V Supply
(1)
(continued)
V
+
= 1.65 V to 1.95 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Dynamic
25°C 1.8 V 9.5 10 12
V
COM
= 1.3 V, C
L
= 35 pF,
Turn-on time t
ON
ns
1.65 V to
R
L
= 300 Ω, See Figure 17
Full 8.5 13
1.95 V
25°C 1.8 V 1.5 2 4
V
COM
= 1.3 V, C
L
= 35 pF,
Turn-off time t
OFF
ns
1.65 V to
R
L
= 300 Ω, See Figure 17
Full 1.5 5.5
1.95 V
Charge V
GEN
= 0,
Q
C
See Figure 20 25°C 1.8 V 1 pC
injection C
L
= 0.1 nF,
NO
V
NO
= V
+
or GND,
OFF C
NO(OFF)
See Figure 16 25°C 1.8 V 6.8 pF
Switch OFF,
capacitance
COM
V
COM
= V
+
or GND,
OFF C
COM(OFF)
See Figure 16 25°C 1.8 V 6.8 pF
Switch OFF,
capacitance
NO
V
NO
= V
+
or GND,
ON C
NO(ON)
See Figure 16 25°C 1.8 V 14 pF
Switch ON,
capacitance
COM
V
COM
= V
+
or GND,
ON C
COM(ON)
See Figure 16 25°C 1.8 V 14 pF
Switch ON,
capacitance
Digital input
C
I
V
I
= V
+
or GND, See Figure 16 25°C 1.8 V 2.2 pF
capacitance
R
L
= 50 Ω,
Bandwidth BW See Figure 18 25°C 1.8 V 400 MHz
Switch ON,
R
L
= 50 Ω, Switch OFF,
OFF isolation O
ISO
25°C 1.8 V –68 dB
f = 10 MHz, See Figure 19
Total harmonic R
L
= 600 Ω, f = 20 Hz to 20 kHz,
THD 25°C 1.8 V 0.32 %
distortion C
L
= 50 pF, See Figure 21
Supply
25°C 0.05 1
Positive supply
I
+
V
I
= V
+
or GND, Switch ON or OFF 1.95 V μA
current
Full 5
10 Submit Documentation Feedback Copyright © 2005–2012, Texas Instruments Incorporated
Product Folder Links: TS5A1066