Datasheet


    
     
SCDS172A - JULY 2004 − REVISED DECEMBER 2004
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V 0.3 V (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
MAX UNIT
V
IK
EN, IN V
CC
= 3 V, I
IN
= −18 mA −1.8 V
I
IH
EN, IN V
CC
= 3.6 V, V
IN
and V
EN
= 5.5 V ±1 µA
I
IL
EN, IN V
CC
= 3.6 V, V
IN
and V
EN
= GND ±1 µA
I
OZ
§
V
CC
= 3.6 V, V
O
= 0 to 5.5 V, V
I
= 0, Switch OFF ±1 µA
I
OS
V
CC
= 3.6 V, V
O
= 0.5 V
CC
, V
I
= 0, Switch ON 50 mA
I
off
V
CC
= 0, V
O
= 0 to 5.5 V, V
I
= 0 1 µA
I
CC
V
CC
= 3.6 V, I
I/O
= 0, Switch ON or OFF 0.7 1.5 mA
I
CC
EN, IN V
CC
= 3.6 V, One input at 3 V, Other inputs at V
CC
or GND 30 µA
I
CCD
V
CC
= 3.6 V,
D and S ports open,
V
EN
= GND,
V
IN
input switching 50% duty cycle
0.35
mA/
MHz
C
IN
EN, IN V
IN
or V
EN
= 5.5 V, 3.3 V or 0, f = 1 MHz 2.5 3.5 pF
C
OFF
D port
f = 1 MHz,
Outputs open,
Switch OFF
5.5 7
pF
C
OFF
S port
I
f = 1 MHz,
Outputs open,
Switch OFF
3.5 5
pF
C
ON
V
I
= 5.5 V, 3.3 V, or 0, f = 1 MHz, Outputs open, Switch ON 10.5 14 pF
r
on
#
V
I
= 1 V, I
O
= 13 mA 3 6
r
on
#
CC
V
I
= 2 V, I
O
= 26 mA 3 6
r
on(flat)
||
V
CC
= 3.3 V, V
I
= 0 to V
CC
, I
O
= 26 mA 1
V
I
, V
O
, I
I
, and I
O
refer to I/O pins.
All typical values are at V
CC
= 3.3 V (unless otherwise noted), T
A
= 25°C.
§
For I/O ports, the parameter I
OZ
includes the input leakage current.
The I
OS
test is applicable to only one ON channel at a time. The duration of this test is less than 1 s.
#
Measured by the voltage drop between the D and S terminals at the indicated current through the switch. ON-state resistance is determined by
the lower of the voltages of the two (D or S) terminals.
||
r
on(flat)
is the difference of r
on
in a given channel at specified voltages.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V 0.3 V, R
L
= 75 , C
L
= 20 pF (unless otherwise noted) (see Figures 6 and 7)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX UNIT
t
pd(s)
IN
D 2 5 ns
t
ON
IN or EN
S 4 7 ns
t
OFF
IN or EN
S 2 7 ns
dynamic characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V 0.3 V (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP
UNIT
D
G
k
R
L
= 150 , f = 3.58 MHz, See Figure 7 0.2 %
D
P
k
R
L
= 150 , f = 3.58 MHz, See Figure 7 0.1 °
B
W
R
L
= 150 , See Figure 8 500 MHz
X
TALK
R
L
= 150 , f = 10 MHz, R
IN
= 10 , See Figure 9 −80 dB
O
IRR
R
L
= 150 , f = 10 MHz, See Figure 10 −60 dB
All typical values are at V
CC
= 3.3 V (unless otherwise noted), T
A
= 25°C.
k
D
G
and D
P
are expressed in absolute magnitude.