Datasheet

Network Analyzer
(HP8753ES)
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
DD
V
BIAS
C
L
= 10 pF
(see Note A)
TS3L501E
www.ti.com
SCDS307A SEPTEMBER 2010REVISED SEPTEMBER 2010
PARAMETER MEASUREMENT INFORMATION
A. C
L
includes probe and jig capacitance.
Figure 7. Test Circuit for Frequency Response (BW)
Frequency response is measured at the output of the ON channel. For example, when V
SEL
= 0 and A
0
is the
input, the output is measured at 0B
1
. All unused analog I/O ports are left open.
HP8753ES Setup
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): TS3L501E