Datasheet

TS3L501E
www.ti.com
SCDS307A SEPTEMBER 2010REVISED SEPTEMBER 2010
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
DD
= 3.3 V ± 0.3 V, R
L
= 200 , C
L
= 10 pF
(unless otherwise noted) (see Figure 5 and Figure 6)
FROM TO
PARAMETER MIN TYP
(1)
MAX UNIT
(INPUT) (OUTPUT)
t
pd
(2)
A or B/C B/C or A 0.3 ns
t
PZH
, t
PZL
SEL A or B/C 0.5 15 ns
t
PHZ
, t
PLZ
SEL A or B/C 0.9 9 ns
t
sk(o)
(3)
A or B/C B/C or A 50 100 ps
t
sk(p)
(4)
A or B/C B/C or A 50 100 ps
t
ON
/t
OFF
(5)
PD A or B/C 250 ns
(1) All typical values are at V
DD
= 3.3 V (unless otherwise noted), T
A
= 25°C.
(2) The propagation delay is the calculated RC time constant of the typical ON-state resistance of the switch and the specified load
capacitance when driven by an ideal voltage source (zero output impedance).
(3) Output skew between center port (A
4
to A
5
) to any other port
(4) Skew between opposite transitions of the same output in a given device |t
PHL
– t
PLH
|
(5) Device enable/disable time from PD
DYNAMIC CHARACTERISTICS
over recommended operating free-air temperature range, V
DD
= 3.3 V ± 0.3 V (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
X
TALK
R
L
= 50 , f = 250 MHz, See Figure 8 –37 dB
O
IRR
R
L
= 50 , f = 250 MHz, See Figure 9 –37 dB
BW See Figure 7 600 MHz
(1) All typical values are at V
CC
= 3.3 V (unless otherwise noted), T
A
= 25°C.
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TS3L501E