Datasheet

Network Analyzer
(HP8753ES)
R
L
= 50 W
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
DD
V
BIAS
0B
2
A
1
1B
1
1B
2
TS3L501E
www.ti.com
SCDS307A SEPTEMBER 2010REVISED SEPTEMBER 2010
PARAMETER MEASUREMENT INFORMATION (continued)
A. C
L
includes probe and jig capacitance.
B. A 50- termination resistor is needed to match the loading of the network analyzer.
Figure 9. Test Circuit for OFF Isolation (O
IRR
)
OFF isolation is measured at the output of the OFF channel. For example, when V
SEL
= GND and A
1
is the input,
the output is measured at 1B
2
. All unused analog input (A) ports are connected to ground, and output (B) ports
are left open.
HP8753ES Setup
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s): TS3L501E