Datasheet
PARAMETER MEASUREMENT INFORMATION (continued)
Network Analyzer
(HP8753ES)
R
L
= 100 Ω
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
CC
V
BIAS
A
1
1B
2
1B
1
R
L
= 100 Ω
2B
1
3B
1
A
2
A
3
0B
2
3B
2
2B
2
HP8753ES Setup
TS3L500AE
www.ti.com
............................................................................................................................................................. SCDS246B – JUNE 2007 – REVISED JUNE 2009
A. C
L
includes probe and jig capacitance.
B. A 50- Ω termination resistor is needed to match the loading of the network analyzer.
Figure 8. Test Circuit for Crosstalk (X
TALK
)
Crosstalk is measured at the output of the nonadjacent ON channel. For example, when V
SEL
= 0 and A
1
is the
input, the output is measured at A
3
. All unused analog input (A) ports are connected to GND, and output (B)
ports are left open.
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
Copyright © 2007 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s): TS3L500AE