Datasheet
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Network Analyzer
(HP8753ES)
R
L
= 100 Ω
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
CC
V
BIAS
0B
2
A
1
1B
1
1B
2
HP8753ES Setup
TS3L4892
16-BIT TO 8-BIT SPDT GIGABIT LAN SWITCH
WITH LED SWITCH
SCDS251 – MARCH 2008
A. C
L
includes probe and jig capacitance.
B. A 50- Ω termination resistor is needed to match the loading of the network analyzer.
Figure 9. Test Circuit for Off Isolation (O
IRR
)
OFF isolation is measured at the output of the OFF channel. For example, when VSEL = V
CC
and A
0
is the input,
the output is measured at 0B
2
. All unused analog input (A) ports are left open, and output (B) ports are
connected to GND through 50- Ω pulldown resistors.
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s): TS3L4892