Datasheet
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Network Analyzer
(HP8753ES)
R
L
= 100 Ω
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
DD
V
BIAS
A
1
1B
2
1B
1
R
L
= 100 Ω
2B
1
3B
1
A
2
A
3
0B
2
3B
2
2B
2
HP8753ES Setup
TS3L301
16-BIT TO 8-BIT SPDT GIGABIT LAN SWITCH
WITH LOW AND FLAT ON-STATE RESISTANCE
SCDS178C – NOVEMBER 2004 – REVISED APRIL 2006
A. C
L
includes probe and jig capacitance.
B. A 50- Ω termination resistor is needed to match the loading of the network analyzer.
Figure 7. Test Circuit for Crosstalk (X
TALK
)
Crosstalk is measured at the output of the nonadjacent ON channel. For example, when V
SEL
= 0 and A
1
is the
input, the output is measured at A
3
. All unused analog input (A) ports are connected to GND, and output (B)
ports are left open.
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
11
Submit Documentation Feedback