Datasheet
Table Of Contents
- FEATURES
- Applications
- DESCRIPTION/ORDERING INFORMATION
- Absolute Maximum Ratings
- Recommended Operating Conditions
- Electrical Characteristics
- Switching Characteristics
- Dynamic Characteristics
- OPERATING CHARACTERISTICS
- APPLICATION INFORMATION
- PARAMETER MEASUREMENT INFORMATION(Enable and Disable Times)
- PARAMETER MEASUREMENT INFORMATION(Skew)
- PARAMETER MEASUREMENT INFORMATION
- PARAMETER MEASUREMENT INFORMATION
- PARAMETER MEASUREMENT INFORMATION

Network Analyzer
(HP8753ES)
R
L
= 100 Ω
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
CC
V
BIAS
0B
2
NOTES: A. C
L
includes probe and jig capacitance.
B. A 50-Ω termination resistor is needed to match the loading of the network analyzer.
A
1
1B
1
1B
2
TS3DV520
SCDS197D –DECEMBER 2005–REVISED OCTOBER 2009
www.ti.com
PARAMETER MEASUREMENT INFORMATION
Figure 9. Test Circuit for OFF Isolation (O
IRR
)
OFF isolation is measured at the output of the OFF channel. For example, when V
SEL
= V
CC
and A
0
is the input,
the output is measured at 0B
2
. All unused analog input (A) ports are left open, and output (B) ports are
connected to GND through 50-Ω pulldown resistors.
HP8753ES setup
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2
P1 = 0 dBM
12 Submit Documentation Feedback Copyright © 2005–2009, Texas Instruments Incorporated
Product Folder Link(s): TS3DV520