Datasheet
www.ti.com
Electrical Characteristics
(1)
Switching Characteristics
Dynamic Characteristics
TS3DV416
4-CHANNEL DIFFERENTIAL 8:16 MULTIPLEXER SWITCH
FOR DVI/HDMI APPLICATIONS
SCDS198C – OCTOBER 2005 – REVISED MAY 2006
for high-frequency switching over recommended operating free-air temperature range, V
DD
= 3.3 V ± 0.3 V
(unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
V
IK
SEL V
DD
= 3.6 V, I
IN
= –18 mA –0.7 –1.2 V
I
IH
SEL V
DD
= 3.6 V, V
IN
= V
DD
± 1 µ A
I
IL
SEL V
DD
= 3.6 V, V
IN
= GND ± 1 µ A
I
off
V
DD
= 0, V
O
= 0 to 3.6 V, V
I
= 0 1 µ A
I
DD
V
DD
= 3.6 V, I
I/O
= 0, Switch ON or OFF 250 600 µ A
C
IN
SEL f = 1 MHz, V
IN
= 0 2.5 3 pF
C
OFF
B port V
I
= 0, f = 1 MHz, Outputs open, Switch OFF 3.5 4 pF
C
ON
V
I
= 0, f = 1 MHz, Outputs open, Switch ON 10 10.9 pF
r
on
V
DD
= 3 V, 1.5 V ≤ V
I
≤ V
DD
, I
O
= –40 mA 4 8 Ω
r
on(flat)
(3)
V
DD
= 3 V, V
I
= 1.5 V and V
DD
, I
O
= –40 mA 0.7 Ω
∆ r
on
(4)
V
DD
= 3 V, 1.5 V ≤ V
I
≤ V
DD
, I
O
= –40 mA 0.2 1.2 Ω
(1) V
I
, V
O
, I
I
, and I
O
refer to I/O pins. V
IN
refers to the control inputs.
(2) All typical values are at V
DD
= 3.3 V (unless otherwise noted), T
A
= 25 ° C.
(3) r
on(flat)
is the difference of r
on
in a given channel at specified voltages.
(4) ∆ r
on
is the difference of r
on
from center (A
4
, A
5
) ports to any other port.
over recommended operating free-air temperature range, V
DD
= 3.3 V ± 0.3 V, R
L
= 200 Ω , C
L
= 10 pF
(unless otherwise noted) (see Figure 4 and Figure 5 )
FROM TO
PARAMETER MIN TYP
(1)
MAX UNIT
(INPUT) (OUTPUT)
t
pd
(2)
A or B B or A 0.04 ns
t
PZH
, t
PZL
SEL A or B 1.5 11.5 ns
t
PHZ
, t
PLZ
SEL A or B 1 8.5 ns
t
sk(o)
(3)
A or B B or A 0.1 0.2 ns
t
sk(p)
(4)
0.1 0.2 ns
(1) All typical values are at V
DD
= 3.3 V (unless otherwise noted), T
A
= 25 ° C.
(2) The propagation delay is the calculated RC time constant of the typical ON-state resistance of the switch and the specified load
capacitance when driven by an ideal voltage source (zero output impedance).
(3) Output skew between center port (A
4
to A
5
) to any other port
(4) Skew between opposite transitions of the same output in a given device |t
PHL
– t
PLH
|
over recommended operating free-air temperature range, V
DD
= 3.3 V ± 0.3 V (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
X
TALK
R
L
= 100 Ω , f = 250 MHz, See Figure 7 –41 dB
O
IRR
R
L
= 100 Ω , f = 250 MHz, See Figure 8 –39 dB
BW See Figure 6 900 MHz
(1) All typical values are at V
DD
= 3.3 V (unless otherwise noted), T
A
= 25 ° C.
5
Submit Documentation Feedback