Datasheet

TS3DV20812
www.ti.com
SCDS302 JUNE 2010
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD
Supply voltage range –0.5 4.6 V
V
IN
Control input voltage range
(2)(3)
SEL –0.5 7 V
I/O –0.5 7 V
V
IO
Switch I/O voltage range (all three I/O ports)
(4)
D0-D3, Aux, HPD, CAD/CEC –0.5 V
CC
+ 0.5 V
A port and B port –0.5 V
CC
+ 0.5 V
I
IK
Control input clamp current V
IN
< 0 –50 mA
I
I/OK
I/O port clamp current V
O
< 0 –50 mA
I
IO
Continuous output current
(5)
ON-state switch ±128 mA
Continuous current through VDD or GND ±100 mA
Θ
JA
Package thermal impedance
(6)
RHH package 31.8 °C/W
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(4) V
I
and V
O
are used to denote specific conditions for V
IO
.
(5) I
I
and I
O
are used to denote specific conditions for I
IO
.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
DD
Supply voltage 2.25 3. 6 V
V
IH
High-level control input voltage SEL 2 5.5 V
V
IL
Low-level control input voltage SEL 0 0.8 V
V
I/O
Input/output voltage All ports 0 5.5 V
V
ANALOG
Analog signal range Differential signal range 0 V
DD
V
V
I
Input tolerant SEL 0 5.5 V
T
A
Operating free-air temperature –40 85 °C
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TS3DV20812