Datasheet
ABSOLUTE MINIMUM AND MAXIMUM RATINGS
(1) (2)
PACKAGE THERMAL IMPEDANCE
TS3A5017
www.ti.com
.......................................................................................................................................... SCDS188D – JANUARY 2005 – REVISED DECEMBER 2008
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
+
Supply voltage
(3)
– 0.5 4.6 V
V
S
, V
D
Analog voltage
(3) (4)
– 0.5 4.6 V
I
SK
,
Analog port clamp current V
S
, V
D
< 0 – 50 mA
I
DK
I
S
, I
D
On-state switch current V
S
, V
D
= 0 to 7 V – 128 128 mA
V
I
Digital input voltage – 0.5 4.6 V
I
IK
Digital input clamp current
(3) (4)
V
I
< 0 – 50 mA
I
+
Continuous current through V
+
100 mA
I
GND
Continuous current through GND – 100 mA
T
stg
Storage temperature – 65 150 ° C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(3) All voltages are with respect to ground, unless otherwise specified.
(4) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
UNIT
D package 73
DB package 82
DGV package 120
θ
JA
Package thermal impedance
(1)
° C/W
DW package 108
RGY package 91.6
RSV package 184
(1) The package thermal impedance is calculated in accordance with JESD 51-7.
Copyright © 2005 – 2008, Texas Instruments Incorporated Submit Documentation Feedback 3