Datasheet

www.ti.com
ELECTRICAL CHARACTERISTICS FOR 1.8-V SUPPLY
(1) (2)
TS3A4741 , , TS3A4742
0.9- LOW-VOLTAGE SINGLE-SUPPLY
DUAL SPST ANALOG SWITCHES
SCDS228D AUGUST 2006 REVISED JANUARY 2008
V
+
= 1.65 V to 1.95 V, T
A
= 40 ° C to 85 ° C, V
IH
= 1 V, V
IL
= 0.4 V (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
MIN TYP
(3)
MAX UNIT
Analog Switch
Analog signal range V
COM
, V
NO
0 V
+
V
25 ° C 1 1.5
V
+
= 1.8 V, I
COM
= 10 mA,
ON-state resistance r
on
V
NO
= 0.9 V
Full 2
25 ° C 0.09 0.15
ON-state resistance match V
+
= 1.8 V, I
COM
= 10 mA,
Δ r
on
between channels
(4)
V
NO
= 0.9 V
Full 0.25
25 ° C 0.7 0.9
ON-state resistance V
+
= 1.8 V, I
COM
= 10 mA,
r
on(flat)
flatness
(5)
0 V
NO
V
+
Full 1.5
25 ° C 1 0.5 1
NO V
+
= 1.95 V, V
COM
= 0.15 V, 1.65 V,
I
NO(OFF)
nA
OFF leakage current
(6)
V
NO
= 1.8 V, 0.15 V
Full 10 10
25 ° C 1 0.5 1
COM V
+
= 1.95 V, V
COM
= 0.15 V, 1.65 V,
I
COM(OFF)
nA
OFF leakage current
(6)
V
NO
= 1.8 V, 0.15 V
Full 10 10
25 ° C 1 0.01 1
COM V
+
= 1.95 V, V
COM
= 0.15 V, 1.65 V,
I
COM(ON)
nA
ON leakage current
(6)
V
NO
= 0.15 V, 1.65 V, or floating
Full 3 3
Dynamic
25 ° C 6 18
V
NO
= 1.5 V, R
L
= 50 ,
Turn-on time t
ON
ns
C
L
= 35 pF, See Figure 14
Full 20
25 ° C 5 10
V
NO
= 1.5 V, R
L
= 50 ,
Turn-off time t
OFF
ns
C
L
= 35 pF, See Figure 14
Full 12
V
GEN
= 0, R
GEN
= 0, C
L
= 1 nF,
Charge injection Q
C
25 ° C 3.2 pC
See Figure 15
NO OFF capacitance C
NO(OFF)
f = 1 MHz, See Figure 16 25 ° C 23 pF
COM OFF capacitance C
COM(OFF)
f = 1 MHz, See Figure 16 25 ° C 20 pF
COM ON capacitance C
COM(ON)
f = 1 MHz, See Figure 16 25 ° C 43 pF
Bandwidth BW R
L
= 50 , Switch ON 25 ° C 123 MHz
f = 10 MHz 61
R
L
= 50 , C
L
= 5 pF,
OFF isolation
(7)
O
ISO
25 ° C dB
See Figure 17
f = 100 MHz 36
f = 10 MHz 95
R
L
= 50 , C
L
= 5 pF,
Crosstalk X
TALK
25 ° C dB
See Figure 17
f = 100 MHz 73
R
L
= 32 0.14
f = 20 Hz to 20 kHz, V
COM
Total harmonic distortion THD 25 ° C %
= 2 V
P-P
R
L
= 600 0.013
Digital Control Inputs (IN1, IN2)
Input logic high V
IH
Full 1 V
Input logic low V
IL
Full 0.4 V
25 ° C 0.1 5
Input leakage current I
IN
V
I
= 0 or V
+
nA
Full 10 10
Supply
Power-supply range V
+
1.65 1.95 V
25 ° C 0.05
Positive-supply current I
+
V
I
= 0 or V
+
µ A
Full 0.5
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(2) Parts are tested at 85 ° C and specified by design and correlation over the full temperature range.
(3) Typical values are at T
A
= 25 ° C.
(4) Δ r
on
= r
on(max)
r
on(min)
(5) Flatness is defined as the difference between the maximum and minimum value of r
on
as measured over the specified analog signal
ranges.
(6) Leakage parameters are 100% tested at the maximum-rated hot operating temperature and specified by correlation at T
A
= 25 ° C.
(7) OFF isolation = 20
log
10 (V
COM
/V
NO
), V
COM
= output, V
NO
= input to OFF switch
4 Submit Documentation Feedback Copyright © 2006 2008, Texas Instruments Incorporated
Product Folder Link(s): TS3A4741 TS3A4742