Datasheet
ELECTRICAL CHARACTERISTICS FOR 3.3-V SUPPLY
(1)
TS3A44159
SCDS225A – MARCH 2007 – REVISED JUNE 2008 .........................................................................................................................................................
www.ti.com
V
+
= 3 V to 3.6 V, T
A
= – 40 ° C to 85 ° C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal V
COM
,
0 V
+
V
range V
NO
, V
NC
25 ° C 0.37 0.55
ON-state V
NO
or V
NC
= 2.0 V, Switch ON,
r
on
3 V Ω
resistance I
COM
= – 100 mA, See Figure 16
Full 0.6
ON-state V
NO
or V
NC
= 2.0 V, 0.8 25 ° C 0.06 0.07
Switch ON,
resistance match Δ r
on
V, 3 V Ω
See Figure 16
Full 0.1
between channels I
COM
= – 100 mA,
ON-state 25 ° C 0.05 0.1
V
NO
or V
NC
= 2.0 V, 0.8 V Switch ON,
resistance r
on(flat)
3 V Ω
I
COM
= – 100 mA, See Figure 16
Full 0.1
flatness
V
NO
or V
NC
= 0.3 V, 25 ° C – 15 5 15
NC, NO V
COM
= 3.0 V,
I
NO(OFF)
,
OFF leakage or See Figure 17 3.6 V nA
I
NC(OFF)
Full – 50 50
current V
NO
or V
NC
= 3.0 V,
V
COM
= 0.3 V,
V
NO
or V
NC
= 0.3 V, 25 ° C – 15 5 15
NC, NO V
COM
= Open,
I
NO(ON)
,
ON leakage or See Figure 18 3.6 V nA
I
NC(ON)
Full – 50 50
current V
NO
or V
NC
= 3.0 V,
V
COM
= Open,
V
NO
or V
NC
= Open, 25 ° C – 15 5 15
COM V
COM
= 0.3 V,
ON leakage I
COM(ON)
or See Figure 18 3.6 V nA
Full – 50 50
current V
NO
or V
NC
= Open,
V
COM
= 3.0 V,
Digital Control Inputs (IN1-2, IN3-4)
(2)
Input logic high V
IH
Full 1.25 4.3 V
Input logic low V
IL
Full 0 0.8 V
25 ° C 0.5 10
Input leakage
I
IH
, I
IL
V
IN
= 3.6 V or 0 3.6 V nA
current
Full 50
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
(2) All unused digital inputs of the device must be held at V
+
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
6 Submit Documentation Feedback Copyright © 2007 – 2008, Texas Instruments Incorporated
Product Folder Link(s): TS3A44159