Datasheet
TS2PCIE412
www.ti.com
SCDS269C –MARCH 2009–REVISED APRIL 2010
ABSOLUTE MAXIMUM RATINGS
(1) (2)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD
Supply voltage range –0.5 2.5 V
V
IN
Control input voltage range
(2) (3)
–0.5 2.5 V
V
I/O
Switch I/O voltage range
(2) (3) (4)
–0.5 2.5 V
I
IK
Control input clamp current V
IN
< GND –50 mA
I
I/OK
I/O port clamp current V
I/O
< GND –50 mA
I
I/O
ON-state switch current
(5)
100 mA
I
DD
Continuous current through V
DD
100 mA
I
GND
Continuous current through GND –100 mA
T
stg
Storage temperature range. –65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND unless otherwise specifed.
(3) The input voltage and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(4) V
I
and V
O
are used to denote specific conditions for V
I/O
.
(5) I
I
and I
O
are used to denote specific conditions for I
I/O
.
PACKAGE THERMAL IMPEDANCE
over operating free-air temperature range (unless otherwise noted)
UNIT
q
JA
Package thermal impedance
(1)
RUA package 51.2 °C/W
(1) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN TYP MAX UNIT
V
DD
Supply voltage 1.5 1.8 2 V
V
IH
High-level control input voltage (SEL) 0.65 × V
DD
V
V
IL
Low-level control input voltage (SEL) 0.35 × V
DD
V
V
IO
Switch input/output voltage 0 V
DD
V
T
A
Operating free air temperature 0 85 °C
Copyright © 2009–2010, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TS2PCIE412