Datasheet

Network Analyzer
(HP8753ES)
R
L
= 50
EXT TRIGGER
BIAS
P1 P2
DUT
A
0
SEL
0B
1
V
SEL
V
CC
V
BIAS
0B
2
A
1
1B
1
1B
2
TS2PCIE412
SCDS269C MARCH 2009REVISED APRIL 2010
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 10. Test Circuit for Off Isolation (O
IRR
)
OFF isolation is measured at the output of the OFF channel. For example, when V
SEL
= 0 V and A
1
is the input,
the output is measured at 1B
2
. All unused analog input (A) ports are left open, and output (B) ports are
connected to GND through 50- pulldown resistors.
HP8753ES Setup
Average = 4
RBW = 3 kHz
V
BIAS
= 0.35 V
ST = 2 s
P1 = 0 dBM
12 Submit Documentation Feedback Copyright © 2009–2010, Texas Instruments Incorporated