Datasheet

NO1
NO2
50 W
50 W
V
NO1
COM1
Channel ON: NO to COM
Network Analyzer Setup
Source Power = 0 dBm
(632 mV P-P at 50 Wload)
DC Bias = 350 mV
50 W
V
+
GND
V
NO2
Source
Signal
Network Analyzer
COM2
IN
V
I
+
V–
V
+
GND
NO
IN
V
I
COM
50 W
50 W
V
NO
V
COM
Channel ON: NO to COM
Network Analyzer Setup
Source Power = 0 dBm
(632-mV P-P at 50-Wload)
DC Bias = 350 mV
Network Analyzer
Source
Signal
+
V
I
= V
IH
or V
IL
V–
NO
COM
C
L
(1)
V
+
/2
IN
V
I
600
600
Audio Analyzer
Source
Signal
R
L
= 600
C
L
= 50 pF
V
SOURCE
= V
+
P-P f
SOURCE
= 20 Hz to 20 kHz
Channel ON: COM to NO
V
I
= (V
IO
V
+
/2) or -V
+
/2
-V
+
/2
(1)
C
L
includes probe and jig capacitance.
V–
TS12A12511
SCDS248B OCTOBER 2009 REVISED APRIL 2011
www.ti.com
Figure 20. Channel-to-Channel Crosstalk (X
TALK
)
Figure 21. Bandwidth (BW)
Figure 22. Total Harmonic Distortion
14 Copyright © 20092011, Texas Instruments Incorporated