Datasheet

TRS3386E
www.ti.com
SLLS829C APRIL 2007 REVISED MARCH 2011
RECEIVER SECTION
Electrical Characteristics
over operating free-air temperature range, V
CC
= V
L
= 3 V to 5.5 V, C1C4 = 0.1 μF (tested at 3.3 V ± 10%), C1 = 0.047 μF,
C2C4 = 0.33 μF (tested at 5 V ± 10%), T
A
= T
MIN
to T
MAX
(unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
I
off
Output leakage current ROUT, receivers disabled ±0.05 ±10 μA
V
OL
Output voltage low I
OUT
= 1.6 mA 0.4 V
V
OH
Output voltage high I
OUT
= 1 mA V
L
0.6 V
L
0.1 V
V
L
= 5 V 0.8 1.2
V
IT
Input threshold low T
A
= 25°C V
V
L
= 3.3 V 0.6 1.5
V
L
= 5 V 1.8 2.4
V
IT+
Input threshold high T
A
= 25°C V
V
L
= 3.3 V 1.5 2.4
V
hys
Input hysteresis 0.5 V
Input resistance T
A
= 25°C 3 5 7 k
(1) Typical values are at V
CC
= V
L
= 3.3 V, T
A
= 25°C
Switching Characteristics
over operating free-air temperature range, V
CC
= V
L
= 3 V to 5.5 V, C1C4 = 0.1 μF (tested at 3.3 V ± 10%), C1 = 0.047 μF,
C2C4 = 0.33 μF (tested at 5 V ± 10%), T
A
= T
MIN
to T
MAX
(unless otherwise noted)
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
t
PHL
0.15
Receiver propagation delay Receiver input to receiver output, C
L
= 150 pF μs
t
PLH
0.15
t
PHL
t
PLH
Receiver skew 50 ns
t
en
Receiver output enable time From PWRDWN 200 ns
t
dis
Receiver output disable time From PWRDWN 200 ns
(1) Typical values are at V
CC
= V
L
= 3.3 V, T
A
= 25°C.
Copyright © 20072011, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TRS3386E