Datasheet

TRS3386E
SLLS829C APRIL 2007 REVISED MARCH 2011
www.ti.com
Recommended Operating Conditions
MIN MAX UNIT
V
CC
Supply voltage 3 5.5 V
V
L
Supply voltage 2.25 V
CC
V
V
L
= 3 V or 5.5 V 0.8
Input logic threshold low DIN, PWRDWN V
V
L
= 2.3 V 0.6
V
L
= 5.5 V 2.4
Input logic threshold high DIN, PWRDWN V
L
= 3 V 2.0 V
V
L
= 2.7 V 1.4
TRS3386ECPWR 0 70
Operating temperature °C
TRS3386EIPWR 40 85
Receiver input voltage 25 25 V
Electrical Characteristics
over operating free-air temperature range, V
CC
= V
L
= 3 V to 5.5 V, C1C4 = 0.1 μF (tested at 3.3 V ± 10%), C1 = 0.047 μF,
C2C4 = 0.33 μF (tested at 5 V ± 10%) (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
DC Characteristics (V
CC
= 3.3 V or 5 V, T
A
= 25°C)
Powerdown supply current PWRDWN = GND, All inputs at V
CC
or GND 1 10 μA
Supply current PWRDWN = V
CC
, No load 0.3 1 mA
(1) Typical values are at V
CC
= V
L
= 3.3 V, T
A
= 25°C.
ESD Protection
PARAMETER TEST CONDITIONS TYP UNIT
Human-Body Model ±15
RIN, DOUT IEC 61000-4-2 Air-Gap Discharge ±15 kV
IEC 61000-4-2 Contact Discharge ±8
4 Submit Documentation Feedback Copyright © 20072011, Texas Instruments Incorporated
Product Folder Link(s): TRS3386E