Datasheet
TRS3318E
www.ti.com
SLLS805B –APRIL 2007–REVISED OCTOBER 2013
Supply Current Section
Electrical Characteristics
over recommended ranges of supply voltage and operating free-air temperature,
V
CC
= 2.25 V to 3 V, C1–C4 = 0.1 µF, T
A
= T
MIN
to T
MAX
(unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
DC Characteristics (V
CC
= 2.5 V, T
A
= 25°C)
Auto-powerdown plus supply current FORCEON = GND, FORCEOFF = V
CC
, All RIN and DIN idle 1 10 µA
Auto-powerdown supply current FORCEOFF = GND 1 10 µA
Supply current FORCEON = FORCEOFF = V
CC
, No load 0.3 2 mA
(1) Typical values are at V
CC
= 2.5 V, T
A
= 25°C.
ESD Protection
PARAMETER TEST CONDITIONS TYP UNIT
HBM ±15
RIN, DOUT IEC 61000-4-2 Air-Gap Discharge method ±15 kV
IEC 61000-4-2 Contact Discharge method ±8
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TRS3318E