Datasheet
TRS3253E
SLLS850B –JANUARY 2008–REVISED NOVEMBER 2009
www.ti.com
TERMINAL FUNCTIONS
TERMINAL
DESCRIPTION
NAME RSM
C1+, C2+ 29, 1 Positive terminal of the voltage-doubler charge-pump capacitor
V+ 30 5.5-V supply generated by the charge pump
C1–, C2- 31, 2 Negative terminal of the voltage-doubler charge-pump capacitor
INVALID 6 Invalid Output Pin
V– 3 –5.5-V supply generated by the charge pump
DIN1 4
DIN2 5 Driver inputs
DIN3 7
10, 11,
ROUT5 -
12, 13, Receiver outputs. Swing between 0 and V
L
.
ROUT1
14
V
L
15 Logic-level supply. All CMOS inputs and outputs are referenced to this supply.
17, 18,
RIN5-RIN1 19, 20, RS-232 receiver inputs
21
DOUT3 22
DOUT2 23 RS-232 driver outputs
DOUT1 25
GND 26 Ground
V
CC
27 3-V to 5.5-V supply voltage
FORCEOFF 28 Powerdown Control input (Refer to Truth Table)
FORCEON 9 Powerdown Control input (Refer to Truth Table)
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
to GND –0.3 6 V
V
L
to GND –0.3 V
CC
+ 0.3 V
V+ to GND –0.3 7 V
V– to GND 0.3 –7 V
V+ + |V–|
(2)
13 V
DIN, FORCEOFF to GND, FORCEON to GND –0.3 6
V
I
Input voltage V
RIN to GND ±25
DOUT to GND ±13.2
V
O
Output voltage V
ROUT –0.3 V
L
+ 0.3
Continuous power dissipation T
A
= 70°C, 32-pin RSM (derate 7 mW/°C above 70°C) TBD mW
T
J
Junction temperature 150 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
(2) V+ and V– can have maximum magnitudes of 7 V, but their absolute difference cannot exceed 13 V.
4 Submit Documentation Feedback Copyright © 2008–2009, Texas Instruments Incorporated
Product Folder Link(s): TRS3253E