Datasheet
RECEIVER SECTION
ELECTRICAL CHARACTERISTICS
(1)
SWITCHING CHARACTERISTICS
(1)
ESD PROTECTION
TRS3232E-Q1
www.ti.com
................................................................................................................................................................................................... SLLS964 – MARCH 2009
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 4 )
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
V
OH
High-level output voltage I
OH
= – 1 mA V
CC
– 0.6 V
CC
– 0.1 V
V
OL
Low-level output voltage I
OL
= 1.6 mA 0.4 V
V
CC
= 3.3 V 1.5 2.4
V
IT+
Positive-going input threshold voltage V
V
CC
= 5 V 1.8 2.4
V
CC
= 3.3 V 0.6 1.2
V
IT –
Negative-going input threshold voltage V
V
CC
= 5 V 0.8 1.5
V
hys
Input hysteresis (V
IT+
– V
IT –
) 0.3 V
r
i
Input resistance V
I
= ± 3 V to ± 25 V 3 5 7 k Ω
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25 ° C.
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 3 )
PARAMETER TEST CONDITIONS TYP
(2)
UNIT
t
PLH
Propagation delay time, low- to high-level output 300 ns
C
L
= 150 pF
t
PHL
Propagation delay time, high- to low-level output 300 ns
t
sk(p)
Pulse skew
(3)
300 ns
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25 ° C.
(3) Pulse skew is defined as |t
PLH
– t
PHL
| of each channel of the same device.
TYP UNIT
Human-Body Model (HBM) ± 15
Receiver inputs (RINx) IEC61000-4-2, Air-Gap Discharge ± 15 kV
IEC61000-4-2, Contact Discharge ± 8
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TRS3232E-Q1