Datasheet
ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
(1)
ELECTRICAL CHARACTERISTICS
(1)
TRS3232E-Q1
www.ti.com
................................................................................................................................................................................................... SLLS964 – MARCH 2009
over operating free-air temperature range (unless otherwise noted)
V
CC
Supply voltage range
(2)
– 0.3 V to 6 V
V+ Positive output supply voltage range
(2)
– 0.3 V to 7 V
V – Negative output supply voltage range
(2)
0.3 V to – 7 V
V+ – V – Supply voltage difference
(2)
13 V
Drivers – 0.3 V to 6 V
V
I
Input voltage range
Receivers – 25 V to 25 V
Drivers – 13.2 V to 13.2 V
V
O
Output voltage range
Receivers – 0.3 V to V
CC
+ 0.3 V
θ
JA
Package thermal impedance
(3) (4)
108 ° C/W
T
J
Operating virtual-junction temperature 150 ° C
T
stg
Storage temperature range – 65 ° C to 150 ° C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
(3) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
See Figure 4
MIN NOM MAX UNIT
V
CC
= 3.3 V 3 3.3 3.6
V
CC
Supply voltage V
V
CC
= 5 V 4.5 5 5.5
V
CC
= 3.3 V 2 5.5
V
IH
Driver high-level input voltage, DIN V
V
CC
= 5 V 2.4 5.5
V
IL
Driver low-level input voltage, DIN 0 0.8 V
V
I
Receiver input voltage – 25 25 V
T
A
Operating free-air temperature – 40 125 ° C
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 4 )
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
I
CC
Supply current No load, V
CC
= 3.3 V or 5 V 0.3 1 mA
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25 ° C.
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TRS3232E-Q1