Datasheet
ABSOLUTE MAXIMUM RATINGS
(1) (2)
RECOMMENDED OPERATING CONDITIONS
(1)
ELECTRICAL CHARACTERISTICS
(1)
TRS3223-Q1
www.ti.com
.......................................................................................................................................................................................... SLLS950 – SEPTEMBER 2008
over operating free-air temperature range (unless otherwise noted)
V
CC
Supply voltage range – 0.3 V to 6 V
V+ Positive output supply voltage range – 0.3 V to 7 V
V – Negative output supply voltage range 0.3 V to – 7 V
V+ – V – Supply voltage difference 13 V
Driver, FORCEOFF, FORCEON, EN – 0.3 V to 6 V
V
I
Input voltage range
Receiver – 25 V to 25 V
Driver – 13.2 V to 13.2 V
V
O
Output voltage range
Receiver, INVALID – 0.3 V to V
CC
+ 0.3 V
θ
JA
Package thermal impedance
(3)
83 ° C/W
T
J
Operating virtual-junction temperature 150 ° C
T
stg
Storage temperature range – 65 ° C to 150 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
see Figure 6
MIN NOM MAX UNIT
V
CC
= 3.3 V 3 3.3 3.6
V
CC
Supply voltage V
V
CC
= 5 V 4.5 5 5.5
V
CC
= 3.3 V 2
Driver and control,
V
IH
High-level input voltage V
DIN, EN, FORCEOFF, FORCEON
V
CC
= 5 V 2.4
V
IL
Low-level input voltage Driver and control, DIN, EN, FORCEOFF, FORCEON 0.8 V
Driver and control, DIN, EN, FORCEOFF, FORCEON 0 5.5
V
I
Input voltage V
Receiver – 25 25
T
A
Operating free-air temperature – 40 125 ° C
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 6 )
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
I
I
Input leakage current EN, FORCEOFF, FORCEON ± 0.01 ± 1 µ A
Auto-powerdown No load, FORCEOFF and
0.3 2 mA
disabled FORCEON at V
CC
Powered off V
CC
= 3.3 V or 5 V, No load, FORCEOFF at GND 1 20
I
CC
Supply current
T
A
= 25 ° C
No load, FORCEOFF at V
CC
,
µ A
Auto-powerdown
FORCEON at GND, 1 20
enabled
All RIN are open or grounded
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25 ° C.
Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TRS3223-Q1