Using the TRF7970A EVM With PC GUI
2.3.2 Read Single Block (Command Code 0x20)
The Read Single Block Command is an optional command that requests one block of user memory data
from a VICC, with the block number specified in the request. If the Option_flag is set in the request, the
VICC also will return the block security status. This command can be sent as an addressed or
unaddressed request.
To perform Read Single Block using the GUI:
1. Select the radio button for Read Single Block.
2. Select Tag Flags accordingly (see Figure 7 for one example).
3. Click Set Protocol.
4. Enter the Block number to be read (in hex).
5. Place tags or transponders near enough to the TRF7970A EVM antenna to be read.
6. Click Execute.
Figure 7. Read Single Block Command Example
13
SLOU321 August 2011 TRF7970A Evaluation Module (EVM)
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated