For Q = ~20 (ISO15693 operations):
kR
PAR
29.1
(move to standard value of 1.3k)
For Q = ~10 (ISO14443 and ISO15693 operations):
647
PAR
R
(move to standard value of 680)
Smith Chart simulation for R
PAR
value = 1.3k reveals theoretical parallel and series
capacitor values capacitor values to be 97pF and 51pF, respectively.
(This is < +2% change from the calculated total cap value.)
Smith Chart simulation for R
PAR
value = 680 (standard value) reveals theoretical
parallel and series capacitor values to be 82pF and 69pF, respectively.