Datasheet

Vin
EN
Vout
Iout
www.ti.com
Operation
Connect a 0-A to 100-mA load between an OUT pin at connector J4, and a GND pin at connector J3.
Disable the output by connecting the jumper on JP1 from the EN pin to the OFF pin.
3 Operation
Turn on the input power supply. For initial operation, set the input power supply, VIN J1, to 10 V
Enable the output by reconnecting the jumper on JP1 from the EN pin to the ON pin.
Vary the respective loads and VIN voltages as necessary for test purposes.
4 Test Results
This section provides typical performance waveforms for the TPS7A1601EVM-046 printed-circuit board.
4.1 Turnon Sequence
Figure 1 shows the turnon/off characteristic where VIN is preset to 10 V, the output drives full load, and
the EN turnon is stepped to 10 V (C2, red). The output soft start (C1, yellow) shows a monotonic rise time
of approximately 60 ms. The output voltage start-up ramp is not load dependant.
Figure 1. Turnon Sequence
4.2 Output Load Transient
Figure 2 shows the load transient response (OUT C1, yellow) for a full-load step transient from 10 mA to
100 mA (C4, green). VIN is set at 10 V.
3
SLVU549 December 2011 TPS7A1601EVM-046
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated