Datasheet
www.ti.com
Line Reg. (mV) +
ǒ
%ńV
Ǔ
V
O
ǒ
V
Imax
* 2.7 V
Ǔ
100
1000
ELECTRICAL CHARACTERISTICS
TPS79301-EP , , TPS79318-EP , , TPS79325-EP , , TPS79328-EP
TPS793285-EP , TPS79330-EP , TPS79333-EP , TPS793475-EP
SGLS163B – APRIL 2003 – REVISED NOVEMBER 2006
over recommended operating free-air temperature range, EN = V
I
, T
J
= –55 to 125 ° C and T
J
= –40 to 125 ° C, V
I
= V
O(typ)
+
1 V, I
O
= 1 mA, C
o
= 10 µ F, C
(byp)
= 0.01 µ F (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
I
Input voltage
(1)
2.7 5.5 V
I
O
Continuous output current
(2)
0 200 mA
T
J
Operating junction temperature –55 125 ° C
0 µ A < I
O
< 200 mA, T
J
= –40 to 125 ° C,
0.98 Vo 1.02 Vo
1.22 V ≤ V
O
≤ 5.2 V
(3)
TPS79301
0 µ A < I
O
< 200 mA, T
J
= –55 to 125 ° C, 1.025
0.97 Vo
1.22 V ≤ V
O
≤ 5.2 V
(3)
Vo
T
J
= 25 ° C 1.8
TPS79318
0 µ A < I
O
< 200 mA, 2.8 V < V
I
< 5.5 V 1.764 1.836
T
J
= 25 ° C 2.5
TPS79325
0 µ A < I
O
< 200 mA, 3.5 V < V
I
< 5.5 V 2.45 2.55
T
J
= 25 ° C 2.8
TPS79328
Output voltage V
0 µ A < I
O
< 200 mA, 3.8 V < V
I
< 5.5 V 2.744 2.856
T
J
= 25 ° C 2.85
TPS793285
0 µ A < I
O
< 200 mA, 3.85 V < V
I
< 5.5 V 2.793 2.907
T
J
= 25 ° C 3
TPS79330
0 µ A < I
O
< 200 mA, 4 V < V
I
< 5.5 V 2.94 3.06
T
J
= 25 ° C 3.3
TPS79333
0 µ A < I
O
< 200 mA, 4.3 V < V
I
< 5.5 V 3.234 3.366
T
J
= 25 ° C 4.75
TPS793475
0 µ A < I
O
< 200 mA, 5.25 V < V
I
< 5.5 V 4.655 4.845
0 µ A < I
O
< 200 mA, T
J
= 25 ° C 170
Quiescent current (GND current) µ A
0 µ A < I
O
< 200 mA 220
Load regulation 0 µ A < I
O
< 200 mA, T
J
= 25 ° C 5 mV
V
O
+ 1 V < V
I
≤ 5.5 V, T
J
= 25 ° C 0.05
Output voltage line regulation ( ∆ V
O
/V
O
)
(4)
%/V
V
O
+ 1 V < V
I
≤ 5.5 V 0.12
C
(byp)
= 0.001 µ F 55
C
(byp)
= 0.0047 µ F 36
BW = 200 Hz to 100 kHz,
Output noise voltage (TPS79328) µ V
RMS
I
O
= 200 mA, T
J
= 25 ° C
C
(byp)
= 0.01 µ F 33
C
(byp)
= 0.1 µ F 32
C
(byp)
= 0.001 µ F 50
R
L
= 14 Ω ,
Time, start-up (TPS79328) C
(byp)
= 0.0047 µ F 70 µ s
C
o
= 1 µ F, T
J
= 25 ° C
C
(byp)
= 0.01 µ F 100
Output current limit V
O
= 0 V
(3)
285 600 mA
Standby current EN = 0 V, 2.7 V < V
I
< 5.5 V 0.07 1 µ A
High-level enable input voltage 2.7 V < V
I
< 5.5 V 2 V
Low-level enable input voltage 2.7 V < V
I
< 5.5 V 0.7 V
Input current (EN) EN = 0 –1 1 µ A
(1) To calculate the minimum input voltage for your maximum output current, use the following formula:
V
I
(min) = V
O
(max) + V
DO
(max load)
(2) Continuous output current and operating junction temperature are limited by internal protection circuitry, but it is not recommended that
the device operate under conditions beyond those specified in this table for extended periods of time.
(3) The minimum IN operating voltage is 2.7 V or V
O(typ)
+ 1 V, whichever is greater. The maximum IN voltage is 5.5 V. The maximum
output current is 200 mA.
(4) If V
O
≤ 2.5 V, then V
Imin
= 2.7 V, V
Imax
= 5.5 V:
If V
O
≥ 2.5 V, then V
Imin
= V
O
+ 1 V, V
Imax
= 5.5 V.
4