Datasheet
TPS77101/115/118/127/128/133/150 WITH RESET OUTPUT
TPS77201/215/218/227/228/233/250 WITH POWER GOOD OUTPUT
150-mA LDO REGULATORS WITH 8-PIN MSOP PACKAGING
SLVS225D – FEBRUARY 2000 – REVISED OCTOBER 2000
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
DISSIPATION RATING TABLE – FREE-AIR TEMPERATURES
PACKAGE
AIR FLOW
(CFM)
θ
JA
(°C/W)
θ
JC
(°C/W)
T
A
< 25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
0 266.2 3.84 376 mW 3.76 mW/°C 207 mW 150 mW
DGK
150 255.2 3.92 392 mW 3.92 mW/°C 216 mW 157 mW
DGK
250 242.8 4.21 412 mW 4.12 mW/°C 227 mW 165 mW
recommended operating conditions
MIN MAX UNIT
Input voltage, V
I
†
2.7 10 V
Output voltage range, V
O
1.5 5.5 V
Output current, I
O
(see Note 2) 0 150 mA
Operating virtual junction temperature, T
J
(see Note 2) –40 125
°C
†
To calculate the minimum input voltage for your maximum output current, use the following equation: V
I(min)
= V
O(max)
+ V
DO(max
load)
.
NOTE 2: Continuous current and operating junction temperature are limited by internal protection circuitry, but it is not recommended that the
device operate under conditions beyond those specified in this table for extended periods of time.