Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATING TABLE—FREE-AIR TEMPERATURES
RECOMMENDED OPERATING CONDITIONS
TPS768xxQ
SLVS211L JUNE 1999 REVISED JANUARY 2006
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated
circuits be handled with appropriate precautions. Failure to observe proper handling and installation
procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision
integrated circuits may be more susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
PRODUCT V
OUT
(2)
TPS768 xxQyyyz XX is nominal output voltage (for example, 28 = 2.8 V, 285 = 2.85 V, 01 = Adjustable).
YYY is package designator.
Z is package quantity.
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com .
(2) Custom output voltages are available; minimum order quantities may apply. Contact factory for details and availability.
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE
Input voltage range, V
I
(2)
–0.3 V to 13.5 V
Voltage range at EN –0.3 V to V
I
+ 0.3 V
Maximum PG voltage 16.5 V
Peak output current Internally limited
Continuous total power dissipation See Dissipation Rating Table
Output voltage, V
O
(OUT, FB) 7 V
Operating junction temperature range, T
J
–40 ° C to +125 ° C
Storage temperature range, T
stg
–65 ° C to +150 ° C
ESD rating, HBM 2 kV
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network terminal ground.
AIR FLOW T
A
< +25 ° C DERATING FACTOR T
A
= +70 ° C T
A
= +85 ° C
PACKAGE (CFM) POWER RATING ABOVE T
A
= +25 ° C POWER RATING POWER RATING
0 568.18 mW 5.6818 mW/ ° C 312.5 mW 227.27 mW
D
250 904.15 mW 9.0415 mW/ ° C 497.28 mW 361.66 mW
0 3.1 W 30.7 mW/ ° C 1.7 W 1.2 W
PWP
(1)
250 4.1 W 41.2 mW/ ° C 2.3 W 1.6 W
(1) This parameter is measured with the recommended copper heat sink pattern on a 4-layer, 5-in × 5-in PCB, 1 oz. copper, 4-in × 4-in
coverage (4 in
2
).
MIN MAX UNIT
Input voltage, V
I
(1)
2.7 10 V
Output voltage range, V
O
1.2 5.5 V
Output current, I
O
(2)
0 1.0 A
Operating junction temperature, T
J
(2)
–40 +125 ° C
(1) Minimum V
IN
= V
OUT
+ V
DO
or 2.7 V, whichever is greater.
(2) Continuous current and operating junction temperature are limited by internal protection circuitry, but it is not recommended that the
device operate under conditions beyond those specified in this table for extended periods of time.
2
Submit Documentation Feedback