Datasheet
SLVS181H − DECEMBER 1998 − REVISED JANUARY 2004
www.ti.com
6
electrical characteristics over recommended operating free-air temperature range,
V
I
= V
O(typ)
+ 1 V, I
O
= 1 mA, EN = IN, C
o
= 4.7 µF (unless otherwise noted) (continued)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
O
= 0 mA, T
J
= 25°C 0.2
I
O
= 1 mA, T
J
= 25°C 3
I
O
= 50 mA, T
J
= 25°C 120 150
I
O
= 50 mA 200
TPS76325
I
O
= 75 mA, T
J
= 25°C 180 225
mV
TPS76325
I
O
= 75 mA 300
mV
I
O
= 100 mA, T
J
= 25°C 240 300
I
O
= 100 mA 400
I
O
= 150 mA, T
J
= 25°C 360 450
I
O
= 150 mA 600
I
O
= 0 mA, T
J
= 25°C 0.2
I
O
= 1 mA, T
J
= 25°C 3
I
O
= 50 mA, T
J
= 25°C 100 125
I
O
= 50 mA 166
V
DO
Dropout voltage
TPS76333
I
O
= 75 mA, T
J
= 25°C 150 188
mV
V
DO
Dropout voltage TPS76333
I
O
= 75 mA 250
mV
I
O
= 100 mA, T
J
= 25°C 200 250
I
O
= 100 mA 333
I
O
= 150 mA, T
J
= 25°C 300 375
I
O
= 150 mA 500
I
O
= 0 mA, T
J
= 25°C 0.2
I
O
= 1 mA, T
J
= 25°C 2
I
O
= 50 mA, T
J
= 25°C 60 75
I
O
= 50 mA 100
TPS76350
I
O
= 75 mA, T
J
= 25°C 90 113
mV
TPS76350
I
O
= 75 mA 150
mV
I
O
= 100 mA, T
J
= 25°C 120 150
I
O
= 100 mA 200
I
O
= 150 mA, T
J
= 25°C 180 225
I
O
= 150 mA 300